Available ranges

0-3.75 m, 0-7.5 m, 0-15 m, 0-24 m or
0-5.0 ft, 0-12.5 ft, 0-25 ft, 0-50 ft, 0-100 ft

Range adjustment: 50% to100%
Span adjustment: 45% to 105%
Allowable loop resistance Loop Plus Line
8200 with 48 Vdc by user: 1500 Ohms (max) 8200 with integral DC supply: 500 Ohms (max)
Accuracy: 0.25% at 100% span, 0.35% at 45% span
Power requirements
15 to 48 Vdc 115 Vac ±10% 50/60 Hz
(on-board 30 Vdc power supply) 230 Vac ±10% 50/60 Hz (on-board 30 Vdc power supply)
Operating voltage 15 Vdc – minimum, 48 Vdc – maximum
Operating temperature -13...+185 °F (-25...+85 °C)
Weight
16 lb (7.3 kg)
Safety approvals

FM Cl.I Div.1 Gr. C,D (NEMA Type 4), (FMRS 1T7H9.AE)
CSA Cl.I Gr. C + D encl. 4 (LR 40894-25)

Enclosure
Explosion proof cast aluminum, epoxy painted
Conduit entries: 3/4” NPT
Signal wires: Two (2) conductors