Standard tank connection 3" (76 mm) ANSI DIN 80 (other options available)
Cable entries
4 x M20/M25 [1/2"(13 mm) 3/4" (19 mm) NPT]
Housing
Robust IP 67 housing, Low pressure - aluminum (stainless steel option), High pressure - stainless steel Weight 27 - 60 lb (12 - 27 kg)
Typical HART® devices
Signal Multi drop HART® protocol max. 4 devices
Model NMT averaging temperature bulb
Model NRF HART® tank side display
HART® pressure transmitter
Level alarms
4 relays with potential free change over contacts, freely assignable to measured value
Safety approvals
Prot.:Weather proof;IP67/NEMA4X/Type 4X
(only for stain.steel Drum chamber) XP Class 1, Div. 1, Gp. CD (FM)
Class 1, Div. 1, Gp. CD (CSA)
*Class 1, Div. 1, Gr. CD, CSA Eex d(ia)
XP-AIS Class 1,Div.1,Gp.CD(FM:EEx d(ia))
(pending, only with N6005-2..,5..,6..)
Note: IS Safety Barrier required for all available options when a
453X Temperature Device is used.