Accuracy
Temp.±0.1°C or less (at reference condition)
Water bottom±2mm or better (with 1m probe, at reference condition)
Power supply
Input 16 .... 30VDC (via HART line from host gauge)
Power consumption
6mA@16VDC (Converter only)
6mA@16VDC (Temp. sensor & converter)
12mA@16VDC (WB sensor & converter)
12mA@16VDC (Temp., WB sensor & converter)
Convertor compatibility
Pt100, Cu90, Cu100, PtCu100
Materials

Housing: Diecast aluminum
WB Sensor: SUS 316 (center rod SUS 304 & PFA protected)

Process connection PF 3/4" (NPS 3/4") universal coupling
M20 threaded (Varec 1700 connection only)
Cable entry G (PF) 1/2", NPT 1/2", PG16, M20
Operating temperature

Converter housing: -40 to +85 °C (-40 to +185 °F)
Temp. sensor: -200 to +235 °C (-328 to +455 °F)
WB sensor: -20 ...+100 °C (-4 ...+212 °F)

Temperature sensor Class A Pt100, IEC PUB 751 1983 and / or JIS 1604 1989
Installation height adjuster ±360mm threaded, (SUS 316)
Probe material SUS 316 flexible tube
SUS 316 flexible tube + SUS316 armored mesh
PTFE or Nylon tube
Process connection JIS 10K 50A RF, ANSI 150lb 2" RF
JPI 150lb 50A RF, DIN DN50 PN 10RF
Water bottom sensor Data transmission: 2.5mm coaxial cable & common ground
Operation range: 1m (3.3 ft) and 2m (6.6 ft)
Approvals Protection: Waterproof IP 65
IS class1 Div1 Gp ABCD, FM... pending
EEx ia IIC TB -T6, ATEX... pending